ROHS SV-HVR2800 series Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
Azbil Corporation No. SS2-AVP302-0100 (Rev.14)
- 3 -
Vibration tolerance
2G, 5 to 400 Hz
(with standard mounting kit on Azbil Corporation’s HA
actuator)
Ambient temperature limits
-40°C to 80°C for general model
TIIS Flameproof : -20°C to 55°C
KOSHA Flameproof : -20°C to 55°C
FM Explosionproof : -40°C to 80°C
FM Intrinsically safe : -40°C to 80°C
ISSeP/ATEX Flameproof : -20°C to 70°C
KEMA/ATEX Intrinsically safe: -40°C to 60°C
CSA Explosionproof : -40°C to 80°C
NEPSI Flameproof : -40°C to 60°C
NEPSI Intrinsically safe
For Ex ia IIC T6 : -40°C to 40°C
For Ex ia IIC T5 : -40°C to 60°C
For Ex ia IIC T4 : -40°C to 80°C
Ambient humidity limits
10% to 90% RH
CE conformity
Electromagnetic compatibility
EN61326-1: 2006 (CE Marking)
Configuration tools
Field Communication Software CommStaff Model
CFS100
HART communicator model 375 or 475 (According to
need, please update a software and device description
files.)
PERFORMANCE SPECIFICATIONS
Accuracy
*1
For 8 mA input signal span < 16 mA
± 1% F.S. (± 2.5% with custom output characteristics)
For 4 mA input signal span < 8 mA
± 1.5% F.S.
Note)*1:Refer to Table 3. Because accuracy varies
depending on the combination of actuator size
and travel.
PHYSICAL SPECIFICATIONS
Enclosure classification
JIS C0920 watertight, NEMA type 4X, IEC529 IP66
Finish
Baked acrylic
Color
Dark blue
Material
Cast aluminum
Weight
For single acting actuator
Without Pressure regulator with filter: 2.5 kg
With Pressure regulator with filter : 3.2 kg
For double acting actuator
Without Pressure regulator with filter: 2.8 kg
With Pressure regulator with filter : 3.5 kg
INSTALLATION
Air connections
Rc1/4 or 1/4NPT internal thread
Electrical connections
G1/2 or 1/2NPT internal thread
Conditions of supply air (JIS C1805-1 (2006))
Particles
Maximum diameter 3 μm
Oil mist
Less than 1 ppm at mass
Humidity of the air supply
The dew point should be at least 10°C lower than the
temperature of this device.
Typical installation
Figure 1 Wiring for model AVP302
Actuator air
Process
fluid
Filtered air supply
Control valve
HART communicator
SVP3000 Alphaplus
Smart Valve Positioner
7
A
B
C
8
H
A
R
T
C
o
m
m
u
n
ic
a
t
o
r
9
G
H
I
4
J
K
L
5
M
N
O
6
P
Q
R
1
S
T
U
2
V
W
X
3
Y
Z
/
0
#
%
&
.
<
>
_
*
:
+
D
E
F
O
I
H
A
R
T
F
I
E
L
D
C
O
M
M
U
N
I
C
A
T
I
O
N
S
P
R
O
T
O
C
O
L
F
4
F
3
F
1
F
2
Controller
4 - 20mA DC
I IN
I IN
I OUT+
I OUT-
CommStaff
Model CFS100
Vista de pagina 2
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios